Schölly Fiberoptic GmbH
June 20th, 2008 — adminRobert-Bosch-Straße 1-3
79211 Denzlingen
Germany
Phone: (+49-7666)908-0
Fax: (+49-7666)908-380
http://www.schoelly.de
info@schoelly.de
Company Contacts
Department/ Name Address
Marketing / Thomas Eckert t.eckert@schoelly.de
Produktmanagement / Dirk Barten d.barten@schoelly.de
Vertrieb / Daniel Lacher d.lacher@schoelly.de
Company Figures
Number of employees 100-499
Sales volume 10-49 Mio US $
Export content max. 75%
Year of foundation 1973
Area of business Electronical Equipment / Medical Technology
Laboratory Equipment
Physiotherapy / Orthopaedic Technology / Occupational Therapy
Language: German Language: English Company Profile
solutions in sight
Schölly does not only stand for carefully engineered
high-end products. We are also committed to corporate
ethics and responsibility in dealing with our employees,
customers, business partners, suppliers and
our hometown Denzlingen alike.
For more than 30 years now, we have been maintaining
a corporate culture that is both self-contained
and open to inspiration from the outside world. Our teams
are staffed with professionals who create superior
products of utmost reliability, based on future-oriented,
well-integrated designs.
By focusing our creative energy, we can offer visualization
technology that is tailor-made to the needs of
our customers.
Product Information
01.01.01.02 Instruments and apparatus for ocular diagnosis
Minioptic 25.04.2008
New technologies in optics, processing and application.
Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Endoscope diameter 1.7 mm
Working length 96 mm
Viewing direction 0° standard
Minioptic 25.04.2008
New technologies in optics, processing and application.
Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Endoscope diameter 1.7 mm
Working length 96 mm
Viewing direction 0° standard
Sinuscopes/Rhinoscopes 25.04.2008
New technology in optics, processing and application.
Laser-welded mechanics in stainless steel provide high safety in sterilization.
Saphire windows distal and proximal, validated even for autoclaving at 134ºC during 18-20 minutes.
Specifications :
Diameter 1,7 / 2,7 / 4 mm
Working Length 96 / 110 / 175 / 187 mm
Viewing Direction 0º / 30º / 45º / 70º as standard or wide angle version
Sinuscopes/Rhinoscopes 25.04.2008
New technology in optics, processing and application.
Laser-welded mechanics in stainless steel provide high safety in sterilization.
Saphire windows distal and proximal, validated even for autoclaving at 134ºC during 18-20 minutes.
Specifications :
Diameter 1,7 / 2,7 / 4 mm
Working Length 96 / 110 / 175 / 187 mm
Viewing Direction 0º / 30º / 45º / 70º as standard or wide angle version
01.01.01.02.10 Ophthalmoscopes
01.08.04 Endoscopes and accessories
FlexiLux Universal Borescopes 19.09.2007
Our FlexiLux Universal Line with patented interchangeable objectives is a modular borescope system for various applications in rough and changing industrial environments.
Endoscope diameter 4.0 / 5.5 / 8.0 / 10.0 mm
Working length 135 / 155 / 250/ 260 / 355 / 370 / 455 / 670 / 950 mm
Viewing direction interchangeable objectives 0º / 30° / 45° / 70° / 90° / 110°
Field of view interchangeable objectives 10° / 35° / 40° / 45° / 60° / 85°
FlexiLux Universal Borescopes 19.09.2007
Our FlexiLux Universal Line with patented interchangeable objectives is a modular borescope system for various applications in rough and changing industrial environments.
Endoscope diameter 4.0 / 5.5 / 8.0 / 10.0 mm
Working length 135 / 155 / 250/ 260 / 355 / 370 / 455 / 670 / 950 mm
Viewing direction interchangeable objectives 0º / 30° / 45° / 70° / 90° / 110°
Field of view interchangeable objectives 10° / 35° / 40° / 45° / 60° / 85°
micrendo Endoscope 19.09.2007
Rod lens optic with maximum picture quality. Good overview in production control through wide angle. Viewing direction according to your demands. The Borescopes are specially aligned for critical quality inspection.
Endoscope diameter 1.8 / 2.7 / 2.9 mm
Working length 34 /95 / 120 / 160 / 210 / 302 mm
Viewing direction 0º / 30° / 70°
Field of view 80° / 85°
micrendo Endoscope 19.09.2007
Rod lens optic with maximum picture quality. Good overview in production control through wide angle. Viewing direction according to your demands. The borescopes are specially aligned for critical quality inspection.
Endoscope diameter 4.0 mm
Working length 175 / 302 mm
Viewing direction 0º / 12° / 30° / 45° / 70°
Field of view 70° / 80° / 95° / 100°
micrendo Endoscope 19.09.2007
Designed for internal examination and inspection of very small bores and tubes, the micrendo® borescopes cover a range of working diameters of 1.8 to 2.9 mm. In addition to the standard version with mirror tubes, wide angle and side-view models are also available.
Endoscope diameter 1.8 / 2.7 mm
Working length 95 / 160 / 185 mm
Viewing direction 0º
Field of view 30° / 35°
micrendo Endoscope 19.09.2007
Rod lens optic with maximum picture quality. Good overview in production control through wide angle. Viewing direction according to your demands. The Borescopes are specially aligned for critical quality inspection.
Endoscope diameter 1.8 / 2.7 / 2.9 mm
Working length 34 /95 / 120 / 160 / 210 / 302 mm
Viewing direction 0º / 30° / 70°
Field of view 80° / 85°
micrendo Endoscope 19.09.2007
Rod lens optic with maximum picture quality. Good overview in production control through wide angle. Viewing direction according to your demands. The borescopes are specially aligned for critical quality inspection.
Endoscope diameter 4.0 mm
Working length 175 / 302 mm
Viewing direction 0º / 12° / 30° / 45° / 70°
Field of view 70° / 80° / 95° / 100°
micrendo Endoscope 19.09.2007
Designed for internal examination and inspection of very small bores and tubes, the micrendo® borescopes cover a range of working diameters of 1.8 to 2.9 mm. In addition to the standard version with mirror tubes, wide angle and side-view models are also available.
Endoscope diameter 1.8 / 2.7 mm
Working length 95 / 160 / 185 mm
Viewing direction 0º
Field of view 30° / 35°
01.08.04.02 Arthroscopes
01.08.04.06 Endoscope service
01.08.04.07 Endoscopy systems
01.08.04.11 Hysteroscopes and culdoscopes
01.08.04.12 Laparoscopes
Laparoscopes 19.09.2007
New technologies in optics, processing and application. Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Endoscope diameter 5 / 6.5 / 10.0 mm
Working length 312 / 336 / 344 mm
Viewing direction 0° / 30° wide angle
Laparoscopes 19.09.2007
New technologies in optics, processing and application. Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Endoscope diameter 5 / 6.5 / 10.0 mm
Working length 312 / 336 / 344 mm
Viewing direction 0° / 30° wide angle
Minioptic 19.09.2007
New technologies in optics, processing and application.
Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Endoscope diameter 2 / 3 mm
Working length 241.5 / 302 mm
Viewing direction 0º wide angle
High resolution image bundle
Minioptic 19.09.2007
New technologies in optics, processing and application.
Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Endoscope diameter 2 / 3 mm
Working length 241.5 / 302 mm
Viewing direction 0º wide angle
High resolution image bundle
01.08.04.13 Laryngoscopes
01.08.04.16 Nasal endoscopes
01.08.04.17 Neuroendoscopes
01.08.04.18 Ear endoscopes
01.08.04.22 Urological endoscopes
Cystoscopes 19.09.2007
New technologies in optics, processing and application. Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Working diameter 2.9 / 4 mm
Working lenght 302 mm
Viewing direction 0º / 12º / 30º / 70º as standard or wide angle version
Cystoscopes 19.09.2007
New technologies in optics, processing and application. Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Working diameter 2.9 / 4 mm
Working lenght 302 mm
Viewing direction 0º / 12º / 30º / 70º as standard or wide angle version
Minioptic 19.09.2007
New technologies in optics, processing and application. Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Working diameter 2 mm
Working length 196 mm
Viewing direction 0º standard version
Minioptic 19.09.2007
New technologies in optics, processing and application. Laser-welded mechanics in stainless steel and scratch-resistant sapphire windows distal and proximal provide high safety in sterilization.
Validated even for autoclaving at 134 °C during 18-20 minutes.
Specifications :
Working diameter 2 mm
Working length 196 mm
Viewing direction 0º standard version
01.08.04.23 Video endoscopes, CCD cameras
FlexiVideoscopes 19.09.2007
This enlargement of the successful FlexiScope line can be used with the stationary camera system 180X-301, as well as with the mobile inspection unit MP500 . Beside the connection to a compact 5.6” TFT monitor there exists at first time the possibility of a direct PDA connection, so that results of inspections can be communicated via remote data transmission. The robust probe is protected with a tungsten braid and therefore as well oil as gas resistant. Optional interchangeable objectives and manifold possibilities of combination guarantee the modularity and variaty which are typical for FlexiScope.
Endoscope diameter 6,0 / 8,0 mm
Working length 2000 / 3000 mm
Tip deflection 4 x 150° / 4 x 140° / 4 x 120°
Standard fix objective 0°/50° or 0°/45°
FlexiVideoscopes 19.09.2007
This enlargement of the successful FlexiScope line can be used with the stationary camera system 180X-301, as well as with the mobile inspection unit MP500 . Beside the connection to a compact 5.6” TFT monitor there exists at first time the possibility of a direct PDA connection, so that results of inspections can be communicated via remote data transmission. The robust probe is protected with a tungsten braid and therefore as well oil as gas resistant. Optional interchangeable objectives and manifold possibilities of combination guarantee the modularity and variaty which are typical for FlexiScope.
Endoscope diameter 6,0 / 8,0 mm
Working length 2000 / 3000 mm
Tip deflection 4 x 150° / 4 x 140° / 4 x 120°
Standard fix objective 0°/50° or 0°/45°
01.08.05 Fibre optics equipment
Flex and Stay Light Guides 19.09.2007
Multi-use flex and stay light guide for complex application. Standadized for the use with focus adapter and optical attachments. Including FlexiLux light source connection.
Flex and Stay Light Guides 19.09.2007
Multi-use flex and stay light guide for complex application. Standadized for the use with focus adapter and optical attachments. Including FlexiLux light source connection.
Goose Neck Light Guide - Semiflexibel 19.09.2007
Reflex-reducing black version of the goose neck. Their arms do practicall not wear down due to their vertical set-up; with standart metal endings for use with optical attachements. Including FlexiLux Light Source connection.
Goose Neck Light Guide - Semiflexibel 19.09.2007
Reflex-reducing black version of the goose neck. Their arms do practicall not wear down due to their vertical set-up; with standart metal endings for use with optical attachements. Including FlexiLux Light Source connection.
Halogen 19.09.2007
Powerful light sources used together with reliable fiberoptic light guides are ideal accessories for optical systems that demand high standards for industrial and medical applications. Robust construction and attractive design combined with state-of-the-art technology are features of all FlexiLux cold light sources.
Halogen 19.09.2007
Powerful light sources used together with reliable fiberoptic light guides are ideal accessories for optical systems that demand high standards for industrial and medical applications. Robust construction and attractive design combined with state-of-the-art technology are features of all FlexiLux cold light sources.
LED Illuminators 19.09.2007
Special feature of the Schölly LED illumination is that it does not flicker, as well as its noiseless and vibration-free operation and long lifetime of the LEDs. The compact construction in combination with the possibility of battery-supplied application guarantee easy handling.
LED Illuminators 19.09.2007
Special feature of the Schölly LED illumination is that it does not flicker, as well as its noiseless and vibration-free operation and long lifetime of the LEDs. The compact construction in combination with the possibility of battery-supplied application guarantee easy handling.
Light Guides of Optical Glass 19.09.2007
FlexiLux light guides are heat resistant up to 80 °C and are fitted with an integrated adapter for FlexiLux cold light sources and a ferrule for fixation. Only FD 8mm versions can be used together with optical attachments.
Light Guides of Optical Glass 19.09.2007
FlexiLux light guides are heat resistant up to 80 °C and are fitted with an integrated adapter for FlexiLux cold light sources and a ferrule for fixation. Only FD 8mm versions can be used together with optical attachments.
Line Illumination 19.09.2007
Fiberoptic line illumination creates a homogenous and powerful light. By using a cylindrical lens, a small line or light field can be adjusted, which is most useful for applications with image processing systems.
Line Illumination 19.09.2007
Fiberoptic line illumination creates a homogenous and powerful light. By using a cylindrical lens, a small line or light field can be adjusted, which is most useful for applications with image processing systems.
Metal Halide 19.09.2007
Very compact, light intensive metal halide light source for all applications and demands. The new metal halide lamp technology guarantees a high light intensity with a low power consumption, as well as a xenon-like colour temperature and a long lamp life. A low noise fan with reduced air turbulence guarantees optimized cooling of the light source without disturbing noise development. The light intensity can be manually adjusted via a diaphragm without changing the colour temperature. Developed for video applications and all endoscope dimensions. The Flexilux 50MH can only be connected to fiberoptical light guides with heat insulation adapter LQ,AD.Xenon.FX.
Metal Halide 19.09.2007
Very compact, light intensive metal halide light source for all applications and demands. The new metal halide lamp technology guarantees a high light intensity with a low power consumption, as well as a xenon-like colour temperature and a long lamp life. A low noise fan with reduced air turbulence guarantees optimized cooling of the light source without disturbing noise development. The light intensity can be manually adjusted via a diaphragm without changing the colour temperature. Developed for video applications and all endoscope dimensions. The Flexilux 50MH can only be connected to fiberoptical light guides with heat insulation adapter LQ,AD.Xenon.FX.
Multibranch Light Guides - Fully Flexible 19.09.2007
For use with focus adjunct and optical records. Black metal PVC protection hose. Including FlexiLux light source adapter.
Multibranch Light Guides - Fully Flexible 19.09.2007
For use with focus adjunct and optical records. Black metal PVC protection hose. Including FlexiLux light source adapter.
Ring Illuminators & Accessories 19.09.2007
The FlexiLux ring illuminators comines compact but robust construction with homogeneous, shadow-free illumination of the working area.
Ring Illuminators & Accessories 19.09.2007
The FlexiLux ring illuminators comines compact but robust construction with homogeneous, shadow-free illumination of the working area.