Sentinel Diagnostics is an Italian company with a long and well established background in the development and production of diagnostic kits focusing on Clinical Chemistry and Immunoturbidimetric tests.

Since 1983, Sentinel has privileged the values of quality

through technology and innovation and in over twenty years of activity the company has managed to affirm market presence in over 50 countries.

Sentinel was among the first of many companies in the field

to observe the European Directive 98/79/CE on in-vitro medical-diagnostic devices and has also become fully compliant with American and Canadian norms.

The constant commitment to compliance with the most stringent regulations has allowed Sentinel, throughout the years, to form winning partnerships thus determining

the continuous success and constant growth of the company.

The COMPANY’s main areas of activity are:

· Clinical Chemistry

· Immunoturbidimetry

· Calibrators, Controls

· Quantitative determination of Fecal

Occult Blood - FOB

· Coagulation

· Automatic systems for Clinical and Immunochemistry, for FOB testing and Coagulation

Product Information
02.01 Analyser appliances

02.01.41 Photometers

03.01.08 Devices and systems for glucose determination units

03.01.08.12 Reagents for glucose determination

03.01.10 Devices and systems for haemoglobin determination

03.01.10.01 Diagnostic agents / kits for the determination of glycosylated haemoglobins

03.01.10.06 Reagents for the determination of glycosylated haemoglobins

03.01.11 Controls / Standards / Calibrators clinical chemistry

03.01.12 Units and systems for dry chemistry

03.01.12.02 Diagnostic agents / kits for clinical chemistry

03.01.12.05 Reagents for clinical chemistry
Acid Phosphatase 09.10.2007

Kinetic colorimetric method - Wavelength 405 nm - stable 7 days at 2-8 °C from the preparation date - Temp. 37 °C - Citrate buffer - Substrate chromogen: alpha-naphtylphosphate-Fast Red TR salt - Ratio: Sample/Reagent 1/10 - Kinetic reading - Lag phase 4 min - Reading time 2 min - Linearity 75 U/L.

Albumin Liquid 09.10.2007

Bromcresol green method - Wavelength 625 nm - SINGLE LIQUID REAGENT- Ratio: Sample/Reagent 1/175 - Immediate reading; color stable 1 hour - Linearity 7 g/dL - Human based standard included in the kit.

03.01.12.06 Fully automatic units for clinical chemistry

03.02.08 Units and systems for the determination of immunoglobulins and plasma proteins

03.02.08.01 Diagnostic agents / kits for immunoglobulin and plasma protein determination

03.02.08.03 Control material for immunoglobulin and plasma protein determination

03.02.08.05 Reagents for immunoglobulin and plasma protein determination

03.02.08.06 Turbidimetry

03.02.10 Controls / Standards / Calibrators immunochemistry

03.02.12 Rheumatoid diseases

03.02.12.01 Diagnostic agents / kits for diagnosis of rheumatism

03.02.12.03 Control material for diagnosis of rheumatism

03.02.14 Specific proteins

03.02.14.01 C-reactive proteins (CRP)

03.02.17 Tumor markers

03.02.17.01 Diagnostic agents / kits for tumour marker determination

03.02.17.02 Units and systems for tumour marker determination

03.02.17.03 Control material for tumour marker determination

03.02.17.04 Reagents for tumour marker determination

03.02.17.05 Accessories for tumour marker determination